| Commercial spray is the
spray application of fiber with adhesive to a properly
prepared surface which will remain exposed.
The
application must be impacted in a smooth, uniform manner with adequate
supply of adhesive, to assure a visually attractive, long lasting
application. |
| |
| Blowing Machine:
|
| An all-fiber airlock
machine providing a precise metered flow of fiber and generating
sufficient velocity from the blowers to impact material in
vertical and overhead applications. |
|
EQUIPMENT REQUIREMENT |
|
Container holding
sufficient quantity of adhesive, covered with lid,
protects glue from fiber contamination. The glue kit has
an externally accessible filter system to prevent
clogging of spray nozzle tips and appropriate size,
suction, bypass, and pressure hoses.
The glue kit includes the barrel, lid, in-line filter,
hoses and fittings. The heavy duty plastic barrel and
lid has a 48 gallon (181 liter) capacity. The lid, which
protects the glue from fiber contamination, is fitted
with a PVC stand pipe, an externally replaceable
screen to filter the glue, and a quick disconnecting
fitting. A reinforced suction hose attaches to this
fitting delivering glue to the pump while an overflow
hose recirculates the glue back to the barrel. One
hundred feet (30.5m.) of 3/8" I.D. (9.5mm.) glue hose is
fitted with a coupling for use in attaching it to the
spray nozzle. (When ordering, the pump manufacturer must
be indicated to match appropriate hoses for suction,
pressure, and overflow recirculation.) Various custom
lengths of 3/8" I.D. (10.3mm.) and 1/2" I.D. (12.7mm.)
pressure hose are also available upon request.
|
Click for Details |
Capable of pumping
adhesive with the required pressure (p.s.i.), capacity (g.p.m.)
and smoothness of spray pattern.
Includes: control bypass assembly with pressure
gauge and shut-off ball valve, fittings for input,
discharge and bypass recirculation hoses. Units are
easily cleaned by running water through the system for a
few minutes immediately after use. The TEFC overload
protected electric motor operates on 120/240volt 60hz
and supplies adequate power for standard spray-on
applications. The units are mounted on a steel base with
belt guard and convenient carrying handle. Larger motors
providing higher pressure and capacity are available
upon request on the MP-20 pump and M-03. (230volt/50hz
available for export) [hoses and in-line filter
available upon request] |
|
A narrow, flat orifice
increases the velocity and dispersal of fiber while
maintaining a smooth flowing, multiple jet spray pattern
which will fully encapsulate the fibers.
The commercial nozzle has a narrow, flat orifice to
increase the dispersing, velocity and impact of fiber.
This will maintain a flat, smooth flowing spray pattern
which will fully encapsulate the fibers.
Features:
- all-aluminum spray head
- 2,4,6 or 8 jet
- 2" (5.1cm.) or 2 1/2" (6.4cm.)
diameter connection for insulation supply hose
- stainless steel standard #40015 tips (2" nozzle)
or #4002 tips (2 1/2" nozzle)
- 3/8" (9.5mm.) hose connection with shut-off ball
valve for liquid adhesive supply hose (additional
tip sizes available upon request)
Weight:
- 2" (5.1cm.) nozzle: 1.4 lbs. (.6kg.)
- 2 1/2" (6.4cm.) nozzle: 1.6 lbs. (.7kg.)
|
|
Packages
and Options |
|
Commercial
Nozzles |
349C-2
|
2"
Commercial Spray Nozzle 4 or 6
Jet (Less Tips) |
| |
|
Commercial
Nozzles |
349C-2.5
|
2-1/2"
Commercial Spray Nozzle 4 or 6
Jet (Less Tips) |
| |
|
Commercial
Spray Tips
|
SS4001
|
Commercial
Spray Tips (.026 opening)
|
| |
|
Commercial
Spray Tips
|
SS4002
|
Commercial
Spray Tips (.036 opening)
|
|
|
|
|
|
|
|
|